Home
http://www.virbac.fr/ http://www.boehringer-ingelheim.com/ http://www.novartis.com/ http://www.animalhealth.bayerhealthcare.com/
vetcontact
Vetrinär
Tiermedizin
  WELCOME  
vetcontact
Vetrinär
Tiermedizin
  Privacy Policy  
  Home  
  Login / Newsletter  
vetcontact
Vetrinär
Tiermedizin
  CONTACTS  
vetcontact
Vetrinär
Tiermedizin
  Classifieds  
  New Products  
  VetCompanies  
  VetSchools  
vetcontact
Vetrinär
Tiermedizin
  PROFESSION  
vetcontact
Vetrinär
Tiermedizin
  Edutainment  
  VetAgenda  
  Presentations  
  Posters  
  ESAVS  
  Specialisation  
vetcontact
Vetrinär
Tiermedizin
  INSIGHT  
vetcontact
Vetrinär
Tiermedizin
  Congress News  
  Picture Galleries  
vetcontact
Vetrinär
Tiermedizin
  PRODUCTS  
vetcontact
Vetrinär
Tiermedizin
  Bayer  
  Boehringer Ing.  
  Novartis  
  Virbac

 
  Simply book for less...  
    

Bovine    Equine    Small Animal Practice    Swine Practice    Articles    Vetjournal    
deutsch english español polski francais
Home / WELCOME / Archiv / Equine /     
 
Laparoscopic Obliteration of the Nephrosplenic Space in Horses
The nephrosplenic space in horses is one of the areas which can be affected by severe and life-threatening colics. Is it possible to obliterate the area via laparascopy as a prevention? An interesting descriptive experimental study from the USA.

Five healthy mature horses were included in this study.

One laparoscope and 2 instrument portals were made on the left side of the horse.
The nephrosplenic space was measured and appropriately sized polypropylene mesh was inserted and attached to the dorsolateral splenic capsule and perirenal fascia using helical titanium coils.

All horses had repeat laparoscopy 4 weeks later and were necropsied at intervals 4–14 weeks after mesh placement.

Results: Mean time for laparoscopic mesh placement was 104 minutes.
None of the horses had signs of colic and at 4 weeks all mesh implants were covered by fibrous tissue.
One horse had a descending colon mesenteric adhesion to the mesh.

At necropsy, the fibrous tissue covering the mesh had adhered to itself and pulled the splenic capsule and perirenal fascia into close apposition. Each mesh implant was firmly adhered to the spleen, nephrosplenic ligament, and perirenal fascia.

Conclusions: Laparoscopic mesh placement was easily performed, well tolerated, and provided excellent fibrous obliteration of the nephrosplenic space.

The single important complication observed was a mesenteric adhesion of the descending colon to the mesh in 1 horse.

Laparoscopic placement of polypropylene mesh leads to obliteration of the nephrosplenic space within 4 weeks and should prevent entrapment of viscera in the nephrosplenic space.


Source: EPSTEIN, KIRA L. & PARENTE, ERIC J. (2006): Laparoscopic Obliteration of the Nephrosplenic Space Using Polypropylene Mesh in Five Horses. In: Veterinary Surgery 35 (5), 431-437.




Tell a friend   |   Print version   |   Send this article

EQUINE

Theiler´s disease in a Trakehner caused by contaminated tetanus vaccinemembers
An 11â€yearâ€old Trakehner gelding was presented for evaluation of lethargy, decreased appetite, mild icterus, and elevated hepatic enzyme activities. Physical examination, serum chemistry results, and liver biopsy histopathologic findings were supportive of Theiler`s disease. Polymerase chain reaction (PCR) testing results of serum and liver tissue were positive for nonprimate (equine) hepacivirus (NPHV) and a novel equine parvovirusâ€hepatitis virus (EqPVâ€H). A serious and finally fatal problem, caused by contaminated vaccine.

  • Limbal squamous cell carcinoma in a Rocky Mountain Horse and geneticsmembers
  • Subconjunctival bupivacaine, lidocaine, and mepivacaine and the corneal sensitivity in horsesmembers
  • Clodronate in horses with lamenessmembers
  • Valacyclovir in horses with equine multinodular pulmonary fibrosismembers
  • Radiculopathy associated with forelimb lameness in horsesmembers
  • Biological variations of routine blood parameters in horsesmembers
  • Prognosis for horses with deep digital flexor tendon injury after penetrating woundmembers
  • Possible maternal effect for the pace trait of horsesmembers
  • Flecainide on induced atrial fibrillation in horsesmembers
  • Sonographic technique to identify manica flexoria tears in horsesmembers
  • Novel prototype dynamic laryngoplasty system on arytenoid abductionmembers
  • Lipid peroxidation biomarkers in equine neuroaxonal dystrophymembers


  • [ Home ] [ About ] [ Contact / Request ] [ Privacy Policy ]

    Copyright © 2001-2018 VetContact GmbH
    All rights reserved