Medical records were reviewed, and results of clinicopathologic testing, including plasma ionized and total calcium concentrations, acid-base values, and electrolyte concentrations, were recorded. Cats with AP were grouped on the basis of outcome (survived vs died or were euthanatized), and plasma ionized calcium concentrations, acid-base values, and electrolyte concentrations were compared between groups.
Serum total calcium concentration was low in 19 (41%) cats with AP, and plasma ionized calcium concentration was low in 28 (61%). Cats with AP had a significantly lower median plasma ionized calcium concentration (1.07 mmol/L) than did control cats (1.12 mmol/L). Nineteen (41%) cats with AP died or were euthanatized; these cats had a significantly lower median plasma ionized calcium concentration (1.00 mmol/L) than did cats that survived (1.12 mmol/L). Ten of the 13 cats with AP that had plasma ionized calcium concentrations < or = 1.00 mmol/L died or were euthanatized.
Results suggest that low plasma ionized calcium concentration is common in cats with AP and is associated with a poorer outcome. A grave prognosis and aggressive medical treatment are warranted for cats with AP that have a plasma ionized calcium concentration < or = 1.00 mmol/L.
Source: Kimmel SE, Washabau RJ, Drobatz KJ (2001): Incidence and prognostic value of low plasma ionized calcium concentration in cats with acute pancreatitis: 46 cases (1996-1998). In:
J Am Vet Med Assoc 2001 Oct 15;219(8):1105-9